Example independent damp and timber survey - London
A coherent solid-wall moisture investigation presented in the same broad sequence as a completed DampApp Pro report.
Harbour Building Pathology
Independent damp, timber and building-pathology inspections
Independent Damp and Timber Survey
Westbourne Residential Management
Private managing agent acting for the property owner
28 Example Terrace, Kensington, London, W8 6AA
EPC E (potential C)
Circa 1885 solid-brick mid-terrace with cellar and suspended timber ground floor
Jamie Taylor, CSRT
Independent damp and timber surveyor
Company History
Harbour Building Pathology is a fictional independent practice specialising in evidence-led damp, timber and traditional-building investigations. Recommendations are directed first at observed moisture sources, ventilation defects and affected materials.
Harbour Building Pathology
Independent damp, timber and building-pathology inspections
Legal Disclaimer
This report records a non-destructive inspection of the accessible areas described. It is not a structural design, drainage test, invasive timber survey, valuation or guarantee that concealed defects are absent. Conclusions apply to the evidence available on the inspection date and should be reviewed if opening-up or repair outcomes provide different evidence.
Client Instructions
Investigate reported staining and mould at the front cellar and ground-floor external wall; inspect associated accessible timber and ventilation; record environmental conditions; identify the best-supported moisture mechanism; and provide proportionate next actions and budget allowances.
Executive Summary
The primary working conclusion is localised rainwater penetration. Internal staining, failed paint and the highest comparative moisture readings align with external staining below a cracked hopper and a downpipe joint that leaked during rainfall. Minor mould at the cooler cellar-wall junction is considered secondary to the persistently damp surface.
Elevated pin readings and localised softening were recorded at accessible joist ends beside the affected wall. The concealed extent cannot be established without targeted opening-up. The kitchen extract fan operated; the bathroom fan did not operate when tested.
No distinct low-level moisture profile, generalised raised ground level or accessible plumbing leak was identified. Repair the rainwater defect, restore bathroom extraction, inspect the joist bearings and allow drying before deciding whether plaster replacement or any damp-proofing treatment is justified.
One primary explanation is stated. Alternative causes remain under review only where the evidence or inspection limitations justify them.
Harbour Building Pathology
Independent damp, timber and building-pathology inspections
Scope and Definitions
Accessible internal and external areas were inspected visually and with non-destructive moisture, temperature and relative-humidity measurements. Furniture, fixed finishes and stored contents were not removed. The cellar ceiling limited direct inspection of some joist bearings.
| Term | Meaning in this report |
|---|---|
| Working conclusion | The best-supported explanation at the inspection date, subject to recorded limitations. |
| WME | Wood Moisture Equivalent: a comparative electrical reading requiring material and context interpretation. |
| Dew point | The temperature at which air at the measured vapour content reaches saturation. |
| HHSRS | An assessor-led hazard rating method; arithmetic does not replace assessor judgement or an authority determination. |
Energy Performance Certificate (EPC)
The EPC is recorded as contextual evidence. It does not diagnose dampness, and any insulation recommendation must be considered with the traditional solid-wall fabric and ventilation strategy.
Harbour Building Pathology
Independent damp, timber and building-pathology inspections
Description of Property
Two-storey mid-terraced dwelling with cellar, solid brick external walls, suspended timber ground floor, pitched slate roof and a later rear addition. The front elevation faces north-west. Occupancy was normal for the property size at the inspection.
External Observations
- Local staining and algae below a cracked front rainwater hopper.
- The adjacent downpipe joint leaked during rainfall and discharged partly over paving beside the cellar wall.
- Pointing was locally weathered but generally intact away from the rainwater defect.
- No generalised high external ground level was recorded at the inspected front elevation.
Adequacy of Ventilation
The kitchen intermittent extract fan operated. The bathroom intermittent fan did not operate when tested. Background ventilators were present and unobstructed in the inspected rooms.
Inspection Restrictions
Stored contents restricted parts of the cellar perimeter. Floor finishes and the cellar ceiling prevented full inspection of concealed joist bearings. No destructive opening-up, drainage test or laboratory salt analysis was included.
Harbour Building Pathology
Independent damp, timber and building-pathology inspections
Structural Timber
Accessible front ground-floor joist ends beside the affected wall returned elevated pin readings, with local surface softening to one bearing. No fungal species identification was attempted. Targeted opening-up and assessment by a competent timber or structural specialist is required before repair or treatment is specified.
Damp and Mould
The moisture pattern was focal rather than a continuous low-level band. Surface mould was confined to the cooler cellar-wall junction. No active plumbing leak was visible in the inspected area. The observed rainwater defect and matching internal distribution provide the strongest current explanation.
Atmospheric Conditions
Spot readings describe conditions at the inspection only. They may change with weather, heating, occupancy and ventilation. The internal vapour pressure was modestly above the external reference, but room-wide humidity was not sufficient by itself to explain the focal masonry wetting.
Damp Survey Methodology
- Visual inspection of accessible internal and external fabric.
- Comparative electrical moisture profiling, interpreted against substrate and distribution.
- Pin readings to accessible timber where appropriate.
- Air temperature, relative humidity, dew point and surface-temperature comparison.
- Correlation of internal findings with weather, drainage and external defects.
Harbour Building Pathology
Independent damp, timber and building-pathology inspections
Floor Plan
Environmental Conditions
These are spot readings, not continuous monitoring. Surface conditions and vapour pressure must be interpreted alongside the observed building defect.
Harbour Building Pathology
Independent damp, timber and building-pathology inspections
Condensation Risk Analysis (BS EN ISO 13788)
A steady-state screening calculation was completed for the front solid-brick wall using the recorded construction and selected climate assumptions.
This screening does not model rain penetration, liquid transport, air leakage or hygroscopic buffering. It does not override the separately observed rainwater defect.
| Layer | Thickness | Lambda W/mK | Mu | R m²K/W | sd m |
|---|---|---|---|---|---|
| Internal lime plaster | 18 mm | 0.87 | 7 | 0.021 | 0.126 |
| Solid dense brick | 225 mm | 0.77 | 16 | 0.292 | 3.600 |
| External lime render | 20 mm | 0.87 | 7 | 0.023 | 0.140 |
HHSRS Hazard Assessment (Assessor-entered)
A damp-and-mould entry was requested as a separate assessor-owned record. The likelihood and harm outcomes below are fictional inputs for this example.
The score is computed from the assessor inputs. It is not a local-authority determination and does not by itself establish legal compliance.
| Assessor input | Recorded value |
|---|---|
| Likelihood | 1 in 100 over 12 months |
| Harm outcomes | Extreme 0% - Severe 5% - Serious 20% - Moderate 75% |
| Calculated score | 118 - Category 2 |
| Linked location | Cellar and front ground-floor wall |
Harbour Building Pathology
Independent damp, timber and building-pathology inspections
Weather and Property Orientation - North-West
Light rain occurred during part of the inspection, allowing active leakage at the hopper/downpipe joint to be observed. Weather data and site observations refer to the same inspection period.
Subsoil and Drainage Details
The localised moisture pattern and observed rainwater defect carry more evidential weight than the soil dataset. Soil type alone is not used to diagnose rising damp.
| Dataset field | Recorded result | Interpretation limit |
|---|---|---|
| Soil type | Loam with clay influence | Desk-based context only |
| Clay / sand / silt | 29% / 38% / 33% | Modelled data, not a site sample |
| Drainage characteristic | Moderate | Does not establish foundation drainage |
| pH | 6.7 | No diagnostic conclusion drawn |
Harbour Building Pathology
Independent damp, timber and building-pathology inspections
External Analysis
Rainwater goods - front elevation
Aligned with internal marker D1
- Observation
- Water escaped at the hopper/downpipe joint during rainfall. Staining and algae continued down to paving beside the cellar wall.
- Evidence
- The focal internal moisture profile aligns with the external defect location.
- Interpretation
- The evidence supports localised rainwater penetration as the primary working conclusion.
- Recommendation
- Repair or replace defective components, confirm sound discharge to drainage, water-test after repair and photograph completion. Repeat internal readings after drying.
Pointing and masonry
Front elevation
- Observation
- Local weathering and isolated open joints were recorded around the affected area.
- Interpretation
- Wholesale repointing is not justified by the observed condition.
- Recommendation
- Repair open joints locally using a compatible mortar after the rainwater defect is addressed.
External levels and paving
Front lightwell
- Observation
- No generalised bridging condition was recorded. Paving falls toward the drainage channel but receives leakage from the downpipe joint.
- Recommendation
- Check paving falls and drainage discharge during rainwater-goods repair.
Harbour Building Pathology
Independent damp, timber and building-pathology inspections
Internal Room Findings
Front cellar wall
North-west orientation - marker D1
- Observation
- Local staining, flaking paint and minor mould were recorded. Comparative wall readings reduced away from the focal area. One adjacent joist end showed elevated pin readings and local surface softening.
- Evidence
- Photographs, room readings and the aligned external defect were reviewed together.
- Interpretation
- Local rainwater penetration with secondary surface mould is the best-supported explanation.
- Recommendation
- Repair rainwater goods, open and assess joist ends, clean mould using an appropriate controlled method, dry the wall and repeat the moisture profile before replacing finishes.
Front ground-floor room
Above the affected cellar wall
- Observation
- No visible staining or active mould was recorded to room finishes. The external wall surface was cooler than room air.
- Interpretation
- No active room-surface damp was identified; the cooler surface warrants monitoring.
- Recommendation
- Maintain normal heating and background ventilation, repair the bathroom fan and review if symptoms recur in colder conditions.
Harbour Building Pathology
Independent damp, timber and building-pathology inspections
Indoor Air Quality Assessment Overview
The assessment combines the recorded internal air temperature, relative humidity, external reference and surface temperature. Scores describe the inspection snapshot and a sensitivity model; they do not diagnose the source of localised building moisture.
Environmental Sensitivity Matrix
The projection holds the measured surface offset constant. It illustrates sensitivity and does not forecast future occupancy or weather.
| Shift | Room temperature | Projected room RH | Projected surface RH | Risk band |
|---|---|---|---|---|
| -5°C | 15.0°C | 75.7% | 105.1% | Severe |
| -3°C | 17.0°C | 66.6% | 92.0% | Severe |
| -1°C | 19.0°C | 58.7% | 80.8% | Severe |
| Current | 20.0°C | 55.2% | 75.7% | High |
| +1°C | 21.0°C | 51.9% | 71.0% | Medium |
| +3°C | 23.0°C | 45.9% | 62.5% | Low |
| +5°C | 25.0°C | 40.7% | 55.2% | Low |
Harbour Building Pathology
Independent damp, timber and building-pathology inspections
Independent Surveyor Disclosure
Harbour Building Pathology has no financial interest in the contractor appointed to complete the work. Figures are budget allowances, not quotations. Competitive quotations against an appropriate specification should be obtained before instruction.
Further timber investigation is marked Seek Further Advice because a defensible repair allowance cannot be set before opening-up.
Essential Summary of Costs
| Description | Status | Cost |
|---|---|---|
| Repair hopper/downpipe and confirm drainage discharge | Standard | £480.00 |
| Repair or replace bathroom extract fan and verify airflow | Standard | £325.00 |
| Targeted opening-up and structural timber assessment | Seek Further Advice | - |
Important Notes
- Repair the identified moisture source before replacing finishes.
- Open timber under a safe system of work and assess structural significance before specifying repair or treatment.
- Allow masonry to dry and repeat the moisture profile; remove plaster only where it has lost integrity or further evidence justifies removal.
- Do not specify a chemical damp-proof course, cavity membrane or wholesale replastering without evidence that it addresses a confirmed cause.
- Review any applicable landlord or housing duties separately for the actual tenure and instruction.
Harbour Building Pathology
Independent damp, timber and building-pathology inspections
Declaration
I confirm that this report records the observations, measurements, limitations and working conclusions stated. The primary conclusion is based on the accessible evidence at the inspection date. Further opening-up, repair outcomes or monitoring may require the conclusion and recommendations to be revised.
I have reviewed the report for internal consistency, distinguished observed evidence from inference, and identified where specialist assessment or further investigation is required. Any HHSRS inputs shown are assessor-owned judgements and do not represent a local-authority determination.
Survey prepared and signed by
Jamie Taylor
Jamie Taylor, CSRT
Signed: 24 May 2026 - Reference HBP-2026-0523